A18558-002Intel® NetStructure™ 470 Switch User GuideIntel® NetStructure™470 SwitchUser Guide

Pagina 2

4CHAPTER 1Intel® NetStructure™ 470T and 470F Switches User GuideConnection GuidelinesGeneral• The 470T switch is can auto-negotiate port duplex. It ca

Pagina 3

94CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideEdit an IEEE 802.1Q VLAN (ConfigureMembership)DescriptionUse this screen to change wh

Pagina 4

95Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuConfigure VLANEdit/Delete IEEE 802.1Q VLANEdit an IEEE 802.1Q VLAN (ConfigurePort Ta

Pagina 5

96CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure VLAN ID for Untagged TrafficDescriptionUse this screen to set the switch up

Pagina 6

97Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuConfigure a VLANGVRP/Ingress Filter SettingsNOTEFor GVRP to work, the port mustbe co

Pagina 7

98CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure a Protocol-based VLANDescriptionVLAN operation mode: Changes the type of VL

Pagina 8

99Using Local ManagementCHAPTER 5Local ManagementAdd a Protocol-based VLANDescriptionVLAN Name: Assigns a name to the VLAN. The name can consist of an

Pagina 9

100CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideEdit/Delete a Protocol-based VLAN DescriptionUse this screen to select a VLAN, to e

Pagina 10

101Using Local ManagementCHAPTER 5Local ManagementEdit a Protocol-based VLAN (ConfigureMembership)DescriptionUse this screen to identify which ports a

Pagina 11

102CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideMonitor (Network Statistics)DescriptionSwitch overview: Displays an overview of all

Pagina 12

103Using Local ManagementCHAPTER 5Local ManagementSwitch OverviewDescriptionThis screen provides an overview of activity on the switch—the traffic sen

Pagina 13

5Setting Up the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 1470 Switch SetupCrossover UTP cable (100Mbps) Switch (MDI-X) Hub (MDI-X)

Pagina 14

104CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuidePort Traffic StatisticsDescriptionSelect port: Selects the range of ports to view. Y

Pagina 15

105Using Local ManagementCHAPTER 5Local ManagementBytes sent: Displays the number of error-free bytes (octets) sent over thisport.Frames received: Dis

Pagina 16

106CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuidePort Error StatisticsDescriptionSelect port: Selects the range of ports to view. You

Pagina 17

107Using Local ManagementCHAPTER 5Local ManagementLate collision: Displays the number of collisions detected after theallowable detection period. This

Pagina 18

108CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuidePacket AnalysisDescriptionUse this screen to view a breakdown of the traffic receive

Pagina 19

109Using Local ManagementCHAPTER 5Local ManagementIGMP Snooping StatusDescriptionUse this screen to view the active multicast groups detected by the s

Pagina 20

110CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideBrowse Address TableDescriptionUse this screen to sort through the switch’s MAC addr

Pagina 21

111Using Local ManagementCHAPTER 5Local ManagementTotal addresses in table: Displays the total number of addresses learnedby the switch. This number i

Pagina 22

112CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideVLAN and GVRP Status DescriptionThis screen is available only if there are active ta

Pagina 23

113Using Local ManagementCHAPTER 5Local ManagementToolsDescriptionView switch traps and events (log): Displays events contained in theswitch’s interna

Pagina 24

6CHAPTER 1Intel® NetStructure™ 470T and 470F Switches User Guide

Pagina 25

114CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideSwitch Event LogDescriptionUse this screen to view and navigate the switch’s log. Th

Pagina 26

115Using Local ManagementCHAPTER 5Local ManagementPing a DeviceDescriptionTarget IP address: Type the IP address of the device you want the switchto p

Pagina 27

116CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideUpload Configuration Image FileDescriptionUploads a configuration image file to a TF

Pagina 28

117Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuSave SettingsSave SettingsDescriptionTo permanently save modified IP Settings, you

Pagina 29

118CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User Guide

Pagina 30

119Technical InformationAPPENDIXAppendixTechnicalInformationA119About the Configuration FileA configuration file is an ASCII text file that contains i

Pagina 31

120APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideSave Configuration FileYou can save the changes you make to the switch’s configuraton

Pagina 32

121Technical InformationAPPENDIXAppendixSample Configuration FileThe following is an example of a configuration file. For more explanationand keyword

Pagina 33

122APPENDIXIntel® NetStructure™ 470T and 470F Switches User Guide###### Port Level Configuration ############################################### Sta

Pagina 34

123Technical InformationAPPENDIXAppendix#### Configure a Protocol Based VLAN ############################################## proto_vlan_list={(Vlan,Pro

Pagina 35

Using the Intel®NetStructure™ 470Tand 470F Switches27OverviewChapter 2 provides an overview for using the Intel® NetStructure™ 470Tand 470F Switches w

Pagina 36

124APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideBOOT MenuDescriptionThe BOOT Menu provides a quick way to troubleshoot some of the ba

Pagina 37

125Technical InformationAPPENDIXAppendixUpdate BOOT PROM1 Copy E470PROM.tfp, E470RUN, tfp, and E470.cfg from the ziparchive into a directory that i

Pagina 38

126APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideUpdate FirmwareThe firmware can be updated after the Boot PROM has been successfullyu

Pagina 39

127Technical InformationAPPENDIXAppendixList of Factory Defaults• Software upgrade mode: Network• TFTP Server Address: 0.0.0.0• Load configuration fil

Pagina 40

128APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideTroubleshooting/FAQsHow can I set the speed or duplex on individual ports?Normally th

Pagina 41

129Technical InformationAPPENDIXAppendixI keep getting an intermittent loss of link (or data is notbeing transmitted). Why?• You may be using the wron

Pagina 42

130APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideRegulatory InformationFCC Part 15 Compliance StatementThis product has been tested an

Pagina 43

131Technical InformationAPPENDIXAppendixAVERTISSEMENTLe système a été conçu pour fonctionner dans un cadre de travailnormal. L’emplacement choisi doit

Pagina 44

132APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideWichtige Sicherheitshinweise1. Bitte lesen Sie sich diese Hinweise sorgfältig durch.2

Pagina 45

133Technical InformationAPPENDIXAppendixLimited Hardware WarrantyIntel warrants to the original owner that the hardware product delivered in this pack

Pagina 46

8CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuideSample ConfigurationThe following example illustrates how the 470T and 470F switches c

Pagina 47

134APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideLimited Hardware Warranty (Europe only)Intel warrants to the original owner that the

Pagina 48

135Technical InformationAPPENDIXAppendixLimitation de garantie du matériel (Europe)Intel garantit au propriétaire original que le produit matériel liv

Pagina 49

136APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideGaranzia limitata sull’hardware (valida solo in Europa)Intel garantisce al proprietar

Pagina 50

137Technical InformationAPPENDIXAppendixBeschränkte Hardwaregarantie (Nur für Europa)Intel garantiert dem ursprünglichen Eigentümer, daß die in diesem

Pagina 51

138APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideGarantía limitada de hardware (sólo para Europa)Intel garantiza al propietario origin

Pagina 52

139IntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T and

Pagina 53

140INDEXIntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T

Pagina 55

9Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 SwitchFlow ControlDuring heavy network activity, the switch’s port buffer

Pagina 56

10CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuidePrimary Path from Client A to Server B: Switch A –> Switch CThe switch checks the

Pagina 57

11Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 SwitchIn this example, Client A can communicate with Server B over two d

Pagina 58

12CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuideAlthough there are eight priority levels, the 470 switches can only put apacket into

Pagina 59

13Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 Switch Guidelines• The switch treats aggregated links as a single port.

Pagina 60

Copyright © 2001, Intel Corporation. All rights reserved.Intel Corporation, 5200 NE Elam Young Parkway, Hillsboro OR 97124-6497Intel Corporation assum

Pagina 61

14CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuidePort-based VLANsPort-based VLANs are the simplest and most common form of VLAN. In ap

Pagina 62

15Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 SwitchThe 802.1Q VLAN works by using a tag added to the Ethernet frames.

Pagina 63

16CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuideProtocol-based VLANsIn a protocol-based VLAN, traffic is bridged through specified po

Pagina 64

17Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 SwitchSpanning Tree Protocol and VLANsThe 470 switches support the Spann

Pagina 65

18CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuideGARP (Generic Attribute Registration Protocol) is defined by the IEEE802.1D (1998 Edi

Pagina 66

Using Intel® DeviceView3OverviewIntel® Device View allows you to manage Intel NetStructure™ 470T and470F switches and other supported Intel networkin

Pagina 67

20CHAPTER 3Intel® NetStructure™ 470T and 470F Switches User GuideInstalling Intel Device ViewBefore you install Intel Device View, make sure your PC m

Pagina 68

21Intel Device ViewCHAPTER 3Intel® Device ViewStarting Intel Device ViewInstall either the Windows or Web version of Intel Device View.Windows* versio

Pagina 69

22CHAPTER 3Intel® NetStructure™ 470T and 470F Switches User GuideInstalling a New SwitchAfter you install a new switch on your network, you can use th

Pagina 70

23Intel Device ViewCHAPTER 3Intel® Device ViewDifferent states of the 470 switches are represented by icons in the DeviceTree.Device Tree iconsDevice

Pagina 71

iIntel® NetStructure     470T and 470F Switches User GuideCONTENTSiContents1 Setting up the Intel® NetStructure™ 470T and470F SwitchesOverview..

Pagina 72

24CHAPTER 3Intel® NetStructure™ 470T and 470F Switches User GuideTo refresh the Device TreeRefreshing the Device Tree updates it to show any newly dis

Pagina 73

25Intel Device ViewCHAPTER 3Intel® Device ViewManaging a SwitchTo manage a 470T or 470F switch, double-click the switch icon in theDevice Tree. In the

Pagina 74

26CHAPTER 3Intel® NetStructure™ 470T and 470F Switches User Guide• Group 1 (Statistics): Monitors utilization and error statistics for eachnetwork seg

Pagina 75

Using the WebDevice Manager427OverviewWith the Web Device Manager, which is built into the Intel® NetStructure™470T and 470F Switches, you can use a W

Pagina 76

28CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideNOTEThe default IP address for theswitch is 192.0.2.1. To accessthe switch with the d

Pagina 77

29Using the Web Device ManagerCHAPTER 4Web Device ManagerClick a menu to viewavailable options.2 In the menu, click an option. The corresponding scree

Pagina 78

30CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideIf the option you selected allows you to configure or monitor a specific port,you can

Pagina 79

31Using the Web Device ManagerCHAPTER 4Web Device ManagerConfiguring the Switch’s IP SettingsNote: You must select Manual in the IP Assignment Method

Pagina 80

32CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideConfiguring a PortYou can use the Web Device Manager to enable or disable a port, and

Pagina 81

33Using the Web Device ManagerCHAPTER 4Web Device ManagerManaging User AccountsCreate user accounts to give specific users read or write access to the

Pagina 82

iiCONTENTSIntel® NetStructure     470T and 470F Switches User Guide4 Using the Web Device ManagerOverview...

Pagina 83

34CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User Guide6 In the Access Level box, click an access level. An administrator canview all settin

Pagina 84

35Using the Web Device ManagerCHAPTER 4Web Device ManagerConfiguring VLANsVLANs provide a way to create a logical network grouping without regardto ph

Pagina 85

36CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuidePort-based VLANYou configure a port-based VLAN by creating the VLAN and then addingpa

Pagina 86

37Using the Web Device ManagerCHAPTER 4Web Device ManagerTag-based VLANYou configure a tag-based VLAN by configuring port membership andingress/egress

Pagina 87

38CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User Guide2 Configure ports for egress (outbound) tagging. • Ensure that the VLAN Name field di

Pagina 88

39Using the Web Device ManagerCHAPTER 4Web Device ManagerOptions include:• Default Port VID: Sets the PVID to be assigned to untagged trafficon a give

Pagina 89

40CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideProtocol-based VLANYou configure a protocol-based VLAN by creating the VLAN and thena

Pagina 90

41Using the Web Device ManagerCHAPTER 4Web Device ManagerLink AggregationOn the Web Device Manager’s switch faceplate graphic, a link aggregationis sh

Pagina 91

42CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User Guide• You can manually add MAC addresses to the table. These are calledstatic addresses,

Pagina 92

43Using the Web Device ManagerCHAPTER 4Web Device ManagerSetting Up Priority TaggingWith priority tagging, you can specify a priority value for traffi

Pagina 93

iiiIntel® NetStructure     470T and 470F Switches User GuideCONTENTSConfigure IGMP Snooping ...65Conf

Pagina 94

44CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideConfiguring Community Strings andTrap ReceiversA trap receiver is a computer on the n

Pagina 95

45Using the Web Device ManagerCHAPTER 4Web Device ManagerMonitoring Switch ActivityWith the Web Device Manager you can view traffic, utilization, and

Pagina 96

46CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideViewing/Changing Switch InformationYou can view general information about the switch,

Pagina 97

47Using the Web Device ManagerCHAPTER 4Web Device ManagerUpdating Switch FirmwareOn the Update Firmware screen you can set up the switch to update its

Pagina 98

48CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User Guide5 In the File Name box, type the name of the firmware file.6 Click Submit.The switch

Pagina 99

49Using Local ManagementCHAPTER 5Local ManagementUsing LocalManagement5OverviewAnother way to configure the switch is through the Local Managementinte

Pagina 100

50CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideTo useTelnet1 Open a Telnet application. In Windows 98 or Windows NT*, selectRun from

Pagina 101

51Using Local ManagementCHAPTER 5Local ManagementNavigationThe console menus provide a basic interface for configuring switch options.For navigation t

Pagina 102

52CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideMain Menu (Top Screen)DescriptionThe Main Menu is the starting point for all other Lo

Pagina 103

53Using Local ManagementCHAPTER 5Local ManagementConfigure DeviceDescriptionIP settings: Configures the switch’s IP address, subnet mask, and defaultg

Pagina 104

ivCONTENTSIntel® NetStructure     470T and 470F Switches User GuideMonitor (Network Statistics) ...102S

Pagina 105

54CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideIP SettingsDescriptionSwitch MAC address: Displays the unique hardware address assign

Pagina 106

55Using Local ManagementCHAPTER 5Local ManagementPort SettingsDescriptionConfigure ports: Selects a range of ports to configure (press z).State: Disab

Pagina 107

56CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideFlow ControlDuring times of heavy network activity, the switch’s port buffers canrece

Pagina 108

57Using Local ManagementCHAPTER 5Local ManagementConfigure GBIC Ports (470T only)DescriptionPort 7- and 8-GBIC: Displays the type of GBIC installed on

Pagina 109

58CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuidePriority TaggingDescriptionWith priority tagging, you can specify a priority value fo

Pagina 110

59Using Local ManagementCHAPTER 5Local ManagementSwitch SettingsDescriptionName: Assigns a name to the switch, up to 40 characters long.Location: Assi

Pagina 111

60CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure Advanced Switch SettingsDescriptionHead of Line (HOL) blocking prevention:

Pagina 112

61Using Local ManagementCHAPTER 5Local ManagementConfigure Spanning Tree ProtocolDescriptionThe IEEE 802.1D Spanning Tree Protocol specification preve

Pagina 113

62CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideHello time: Displays the time between transmissions of configurationBPDUs (Bridge Pro

Pagina 114

63Using Local ManagementCHAPTER 5Local ManagementConfigure Spanning Tree for PortsDescriptionPort: Identifies port numbers; select the port you want t

Pagina 115

Setting up the Intel®NetStructure™ 470Tand 470F Switches11OverviewThis guide provides information on configuring and managing the Intel®NetStructure™

Pagina 116

64CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideForwarding and FilteringDescriptionLock address table: Determines if the table learns

Pagina 117

65Using Local ManagementCHAPTER 5Local ManagementConfigure IGMP SnoopingDescriptionIGMP snooping (Internet Group Management Protocol) allows the switc

Pagina 118

66CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure Static MAC AddressesDescriptionStatic MAC addresses are MAC addresses that

Pagina 119

67Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuConfigure DeviceForwarding and FilteringConfigure Port SecurityConfigure Port Securi

Pagina 120

68CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure MAC Address FilteringDescriptionMAC address filtering allows the switch to

Pagina 121

69Using Local ManagementCHAPTER 5Local ManagementConfigure Ethernet Multicast FilteringDescriptionYou can use Ethernet multicast filters to define whi

Pagina 122

70CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideEthernet Multicast Filtering (Ports)DescriptionAction: Blocks or forwards traffic to

Pagina 123

71Using Local ManagementCHAPTER 5Local ManagementPort MirroringDescriptionPort mirroring is a diagnostic tool you can use to send a copy of the goodEt

Pagina 124

72CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideLink AggregationDescriptionLink aggregation is a way of combining ports on the switch

Pagina 125

73Using Local ManagementCHAPTER 5Local Management Broadcast Storm ControlDescriptionYou can use broadcast storm control to filter out broadcasts from

Pagina 126

2CHAPTER 1Intel® NetStructure™ 470T and 470F Switches User GuideSwitch FeaturesThese are the major features of the 470 switches.• 100/1000 Base-T auto

Pagina 127

74CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure Management MenuDescriptionConfigure community strings & trap receivers:

Pagina 128

75Using Local ManagementCHAPTER 5Local ManagementCommunity Strings & Trap ReceiversDescriptionUse this screen to send alerts to PCs with SNMP mana

Pagina 129

76CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideAdminister User AccountsDescriptionAdd Users/Change PasswordsUsername: By default, no

Pagina 130

77Using Local ManagementCHAPTER 5Local ManagementAccess level: Establishes a user’s access rights (press z).Administrators can make any changes to Loc

Pagina 131

78CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideManaging User AccountsSystem Administrators can create up to three user accounts for

Pagina 132

79Using Local ManagementCHAPTER 5Local Management6 To save the new password, press T to select SAVE CHANGES(below the Confirm new password field) and

Pagina 133

80CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideDefine IP Access ListDescriptionUsers with IP addresses defined on the access list ca

Pagina 134

81Using Local ManagementCHAPTER 5Local ManagementUpdate Firmware and Config Files DescriptionSoftware update mode: Choose to update switch firmware o

Pagina 135

82CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideReset and Console OptionsDescriptionReset OptionsReboot switch: Reboots the switch. I

Pagina 136

83Using Local ManagementCHAPTER 5Local ManagementConfigure VLAN Operation Mode DescriptionUse this screen to activate or change the type of VLAN oper

Pagina 137

3Setting Up the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 1470 Switch SetupLEDsThe LEDs to the left of the ports indicate port status, indivi

Pagina 138

84CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideLOCATIONMain MenuConfigure VLANPort-based VLANsDescriptionPort-based VLANs are the si

Pagina 139

85Using Local ManagementCHAPTER 5Local ManagementAdd a Port-based VLAN DescriptionVLAN Name: Assigns a name to the VLAN. Names can consist of anychara

Pagina 140

86CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideTo create a port-based VLAN1 On the Main Menu, select Configure VLAN.Note: Make sure

Pagina 141

87Using Local ManagementCHAPTER 5Local ManagementChange Port Membership in a VLAN DescriptionThis screen is similar to the VLAN creation screen. You

Pagina 142

88CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure 802.1Q VLANs DescriptionVLAN operation mode: Changes the type of VLAN oper

Pagina 143

89Using Local ManagementCHAPTER 5Local ManagementAdd an IEEE 802.1Q VLAN (ConfigurePort Membership)DescriptionVLAN Name: Assigns a name to the VLAN. T

Pagina 144

90CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideAdd an IEEE 802.1Q VLAN (ConfigurePort Tagging)DescriptionVLAN Name: Displays the VLA

Pagina 145

91Using Local ManagementCHAPTER 5Local ManagementConfiguring 802.1Q VLANsSetting up an 802.1Q VLAN is a three-step process. First, create a VLANon the

Pagina 146

92CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideStep 3: Configure VLAN for untagged devicesEven if the device attached to the switch

Pagina 147

93Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuConfigure VLANEdit/Delete an 802.1Q VLANEdit/Delete an 802.1Q VLAN DescriptionUse t