Intel MPRTM0020 Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per no Intel MPRTM0020. Intel MPRTM0020 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Rear Transition Module

Intel NetStructure® MPRTM0020 Rear Transition ModuleTechnical Product SpecificationApril 2006Order Number: 309383-004

Pagina 2

10 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Functional Overview• One SAS x4 connector to support external SAS JBOD. (

Pagina 3 - Contents

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 11Operating the UnitOperating the Unit 33.1 IntroductionThe Intel NetStruct

Pagina 4

12 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Operating the Unit3.4 Digital Ground to Chassis Ground ConnectionDigital

Pagina 5 - – April 2006 5

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 13Operating the UnitNote: Digital ground is also called “logic ground”. Cha

Pagina 6 - Revision History

14 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Module ComponentsModule Components 44.1 Block DiagramFigure 4 shows a fun

Pagina 7 - Document Organization 1

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 15Module Components4.2 Physical LayoutFigure 5. Rear Transition Module (RT

Pagina 8 - Document Organization

16 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Module ComponentsFigure 6 identifies the connectors and LEDs on the RTM f

Pagina 9 - Functional Overview 2

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 17Module Components4.3 Components DescriptionThe following sections describ

Pagina 10 - – April 2006

18 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Module Components4.3.2 USB InterfaceOne USB port is provided on the RTM.

Pagina 11 - Operating the Unit 3

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 19Module Components4.3.4 SAS Connector InterfaceOne x4 SAS (Serial Attached

Pagina 12

2 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCT

Pagina 13 - Operating the Unit

20 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Module ComponentsNote: The SAS_RX3 and SAS_TX3 interfaces are not physica

Pagina 14 - Module Components 4

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 21Module Components4.3.6 Zone 3 Rear Transition Module Power Connector (P30

Pagina 15 - 4.2 Physical Layout

22 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Module Components Figure 12. P30 ConnectorTable 7. P30 Connector Pinout

Pagina 16 - 16 Intel NetStructure

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 23Module Components4.3.7 Zone 3 Rear Transition Module Data/Control Connect

Pagina 17 - Optional Top Ground Tabs

24 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Module Components4.3.7.2 Zone 3 Rear Transition Module Data Connector (P3

Pagina 18 - Gigabit Ethernet Interface

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 25Module ComponentsAP3[x] indicates that these T1/E1 signals are routed fro

Pagina 19 - 4.3.4 SAS Connector Interface

26 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Module Components4.3.10 Power SuppliesThe MPRTM0020 RTM needs several vol

Pagina 20 - Pin 1Pin 3Pin 24Pin 25

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 27Module Components• +1.8V: The 1.8 V voltage is used as the input voltage

Pagina 21 - – April 2006 21

28 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Module Components4.3.13 RJ-45 Gigabit Ethernet Port LEDsThe RJ-45 connect

Pagina 22

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 29Module ComponentsThe LINK LED has the following indications and meanings:

Pagina 23 - – April 2006 23

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 3Contents1 Document Organization ...

Pagina 24

30 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006RTM Management ArchitectureRTM Management Architecture 55.1 IntroductionT

Pagina 25 - 4.3.9 ADM1026 Controller

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 31RTM Management Architecture5.4 Power Budget ManagementThe SBC IPMC has in

Pagina 26 - 4.3.10 Power Supplies

32 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006RTM Management Architecture• RTM Temp2• RTM Temp3• RTM Power StatusTable

Pagina 27 - 4.3.12 Board Status LEDs

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 33Detailed SpecificationsDetailed Specifications 66.1 Dimensions and Weight

Pagina 28

34 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Detailed SpecificationsFigure 17 below shows the locations of major compo

Pagina 29 - – April 2006 29

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 35Detailed Specifications6.4 Reliability Specifications6.4.1 Mean Time Betw

Pagina 30 - RTM Management Architecture 5

36 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Detailed Specifications6.4.1.3 General Notes•Method I, Case I = Based on

Pagina 31 - 5.7 RTM Sensor Proxy

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 37Warranty InformationWarranty Information 77.1 Intel NetStructure® Compute

Pagina 32 - • RTM Power Status

38 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Warranty InformationDirect Return Authorization (DRA) repair requests e-m

Pagina 33 - Detailed Specifications 6

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 39Warranty Information7.2.4 Limitation of Liability and RemediesINTEL SHALL

Pagina 34

4 Intel NetStructure® MPRTM0020 Technical Product Specification – April 20066.4.1 Mean Time Between Failure (MTBF) Specifications ...

Pagina 35 - – April 2006 35

40 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Customer SupportCustomer Support 88.1 Customer SupportThis chapter offers

Pagina 36 - 6.5 Power Consumption

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 41CertificationsCertifications 9Safety:• IEC60950-1• EN60950• UL/CSA 60950-

Pagina 37 - Warranty Information 7

42 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Agency InformationAgency Information 1010.1 North America (FCC Class A)Fe

Pagina 38

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 43Agency InformationCompliance with the R&TTE Directive The R&TTE D

Pagina 39 - – April 2006 39

44 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Safety WarningsSafety Warnings 1111.1 Safety PrecautionsReview the follow

Pagina 40 - Customer Support 8

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 5Tables1 Acronyms and Terms...

Pagina 41 - Certifications 9

6 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Revision HistoryDate Revision DescriptionApril 2006 004Updated values for

Pagina 42 - Agency Information 10

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 7Document OrganizationDocument Organization 1The Intel NetStructure® MPRTM0

Pagina 43 - – April 2006 43

8 Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006Document OrganizationHot Swap A specific specification from the PICMG 3.0

Pagina 44 - Safety Warnings 11

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 9Functional OverviewFunctional Overview 2Rear Transition Modules (RTM) are

Commenti su questo manuale

Nessun commento