Case Temperature Reference Metrology
Thermal and Mechanical Design Guidelines 97
24. You may need to move the solder back toward the groove as the IHS begins to
heat. Use a fine tip tweezers to push the solder into the end of the groove until a
solder ball is built up (Figure 7-28 and Figure 7-29).
Figure 7-28. View Through Lens at Solder Station
Figure 7-29. Moving Solder back onto Thermocouple Bead