Datasheet, Volume 2 235
Processor Configuration Registers
2.16.9 FECTL_REG—Fault Event Control Register
This register specifies the fault event interrupt message control bits. The VTd
specification describes hardware handling of fault events.
B/D/F/Type: 0/0/0/DMIVC1REMAP
Address Offset: 38-3Bh
Reset Value: 80000000h
Access: RW, RO
Bit Attr
Reset
Value
Description
31 RW 1b
Interrupt Mask (IM)
0 = No masking of interrupt. When a interrupt condition is detected,
hardware issues an interrupt message (using the Fault Event Data &
Fault Event Address register values).
1 = This is the value on reset. Software may mask interrupt message
generation by setting this field. Hardware is prohibited from sending the
interrupt message when this field is set.
30 RO 0b
Interrupt Pending (IP)
Hardware sets the IP field whenever it detects an interrupt condition, which is
defined as:
When primary fault logging is active, an interrupt condition occurs when
hardware records a fault through one of the Fault Recording registers
and sets the PPF field in the Fault Status register.
When advanced fault logging is active, an interrupt condition occurs
when hardware records a fault in the first fault record (at index 0) of the
current fault log and sets the APF field in the Fault Status register.
Hardware detected error associated with the Invalidation Queue, setting
the IQE field in the Fault Status register.
Hardware detected invalid Device-IOTLB invalidation completion, setting
the ICE field in the Fault Status register.
Hardware detected Device-IOTLB invalidation completion time-out,
setting the ITE field in the Fault Status register.
If any of the status fields in the Fault Status register was already Set at the
time of setting any of these fields, it is not treated as a new interrupt
condition.
The IP field is kept Set by hardware while the interrupt message is held
pending. The interrupt message could be held pending due to the interrupt
mask (IM field) being Set or other transient hardware conditions.
The IP field is cleared by hardware as soon as the interrupt message pending
condition is serviced.
This could be due to either:
Hardware issuing the interrupt message due to either a change in the
transient hardware condition that caused the interrupt message to be
held pending, or due to software clearing the IM field.
Software servicing all the pending interrupt status fields in the Fault
Status register as follows.
When primary fault logging is active, software clearing the Fault
(F) field in all the Fault Recording registers with faults, causing the
PPF field in the Fault Status register to be evaluated as Clear.
Software clearing other status fields in the Fault Status register by
writing back the value read from the respective fields.
29:0 RO 00..00h Reserved
Vedere la pagina 234
1 2 ... 230 231 232 233 234 235 236 237 238 239 240 ... 359 360

Commenti su questo manuale

Nessun commento

Atec AEMC-6472_6474 manuels

Manuels d'utilisation et guides de l'utilisateur pour Équipement Atec AEMC-6472_6474.
Nous fournissons des manuels en pdf 1 Atec AEMC-6472_6474 à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Équipement Atec

Modèles Type de document
AEMC-4620_4630 Manuel de l'utilisateur   Atec AEMC-4620_4630 User Manual, 6 pages
Biddle-DET-2-2 Manuel de l'utilisateur   Atec Biddle-DET-2-2 User Manual, 2 pages
Chroma-19572 Manuel de l'utilisateur   Atec Chroma-19572 User Manual, 2 pages
AEMC-6416-6417 Manuel de l'utilisateur   Atec AEMC-6416-6417 User Manual, 4 pages
Biddle-DET3-2 Manuel de l'utilisateur   Atec Biddle-DET3-2 User Manual, 5 pages
AEMC-6470 Manuel de l'utilisateur   Atec AEMC-6470 User Manual, 2 pages
Biddle-DET5-2 Manuel de l'utilisateur   Atec Biddle-DET5-2 User Manual, 2 pages
AEMC-6470B Manuel de l'utilisateur   Atec AEMC-6470B User Manual, 8 pages
AEMC-4500 Manuel de l'utilisateur   Atec AEMC-4500 User Manual, 5 pages
AEMC-3620 Manuel de l'utilisateur   Atec AEMC-3620 User Manual, 6 pages
Amplifier-Research-FL7040-Kit Manuel de l'utilisateur   Atec Amplifier-Research-FL7040-Kit User Manual, 2 pages
Amplifier-Research-FP7018 Manuel de l'utilisateur   Atec Amplifier-Research-FP7018 User Manual, 1 pages
AmplifierResearch_FL7060 Manuel de l'utilisateur   Atec AmplifierResearch_FL7060 User Manual, 2 pages
Associated-Research-5030DT Manuel de l'utilisateur   Atec Associated-Research-5030DT User Manual, 4 pages
AmplifierResearch_FP7003-Kit Manuel de l'utilisateur   Atec AmplifierResearch_FP7003-Kit User Manual, 1 pages
Amplifier-Research-FM7004 Manuel de l'utilisateur   Atec Amplifier-Research-FM7004 User Manual, 2 pages
Associated-Research-3130_3140_3160 Manuel de l'utilisateur   Atec Associated-Research-3130_3140_3160 User Manual, 2 pages
Associated-Research-3140-60 Manuel de l'utilisateur   Atec Associated-Research-3140-60 User Manual, 2 pages
ARA-Technologies-PLA-130-A Manuel de l'utilisateur   Atec ARA-Technologies-PLA-130-A User Manual, 2 pages
Emco-6509 Manuel de l'utilisateur   Atec Emco-6509 User Manual, 2 pages