Intel® Workstation Board S5520SC TPS Jumper Blocks
Revision 1.7
Intel order number: E39530-010
119
8. Close the workstation chassis.
9. Power up the workstation.
The password is now cleared and you can reset it by going into the BIOS setup.
7.2 Force BMC Update Procedure
When performing a standard BMC (Baseboard Management Controller) firmware update
procedure, the update utility places the BMC into an update mode, allowing the firmware to load
safely onto the flash device. In the unlikely event the BMC firmware update process fails due to
the BMC not being in the proper update state, the workstation board provides a Force BMC
Update jumper (J1H1) which forces the BMC into the proper update state. In the event the
standard BMC firmware update process fails, you must complete the following procedure.
1. Power down and remove the AC power cord.
2. Open the workstation chassis. Refer your workstation chassis documentation for
instructions.
3. Move the jumper (J1H1) from the default operating position (covering pins 1 and 2) to
the enabled position (covering pins 2 and 3).
4. Close the workstation chassis.
5. Reconnect the AC cord and power up the workstation.
6. Perform the BMC firmware update procedure as documented in the README.TXT file
included in the given BMC firmware update package. After successful completion of the
firmware update process, the firmware update utility may generate an error stating the
BMC is still in update mode.
7. Power down and remove the AC power cord.
8. Open the workstation chassis.
9. Move jumper (J1H1) from the enabled position (covering pins 2 and 3) to the disabled
position (covering pins 1 and 2).
10. Close the workstation chassis.
11. Reconnect the AC power cord and power up the workstation.
Note: Normal BMC functionality is disabled when the Force BMC Update jumper is set to the
enabled position. You should never run the workstation with the Force BMC Update jumper set
in this position. You should only use this jumper setting when the standard firmware update
process fails. This jumper should remain in the default/disabled position when the workstation is
running normally.
7.3 BIOS Recovery
1. Power down the system and remove the AC power cord.
2. Open the workstation chassis. Refer your workstation chassis documentation for
instructions.