Intel® Light Guided Diagnostics Intel® Workstation Board S5520SC TPS
Revision 1.7
Intel order number: E39530-010
124
By issuing the appropriate hex IPMI “Chassis Identify” value, the ID LED either blinks
blue for 15 seconds and turns off or blinks indefinitely until the appropriate hex IPMI
Chassis Identify value is issued to turn it off.
The bi-color (green/amber) System Status LED operates as follows:
Table 74. System Status LED
Color State Criticality Description
Green Solid on System OK System booted and ready.
Green Blink Degraded System degraded
Non-critical temperature threshold asserted
Non-critical voltage threshold asserted
Non-critical fan threshold asserted
Fan redundancy lost, sufficient system cooling maintained. This
does not apply to non-redundant systems.
Power supply predictive failure
Power supply redundancy lost. This does not apply to non-
redundant systems.
Correctable errors over a threshold of 10 and migrating to a
mirrored DIMM (memory mirroring). This indicates the user no
longer has spare DIMMs indicating a redundancy lost condition.
The corresponding DIMM LED should light up.
Amber Blink Non-critical Non-fatal alarm – system is likely to fail:
Critical temperature threshold asserted
CATERR asserted
Critical voltage threshold asserted
VRD hot asserted
SMI Timeout asserted
Amber Solid on Critical, non-
recoverable
Fatal alarm – system has failed or shut down
CPU Missing
Thermal Trip asserted
Non-recoverable temperature threshold asserted
Non-recoverable voltage threshold asserted
Power fault/Power Control Failure
Fan redundancy lost, insufficient system cooling. This does not
apply to non-redundant systems.
Power supply redundancy lost insufficient system power. This
does not apply to non-redundant systems.
Note: This state will also happen when AC power is first applied to the
system. This indicates the BMC is booting.
Off N/A Not ready AC power off, if no degraded, non-critical, critical, or non-
recoverable conditions exist.
System is powered down or S5 states, if no degraded, non-critical,
critical, or non-recoverable conditions exist.