Intel S5520SC Specifiche Pagina 166

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 192
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 165
Appendix C: BMC Sensor Tables Intel® Workstation Board S5520SC TPS
Revision 1.7
Intel order number: E39530-010
152
Table 86. Integrated BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Readin
g Type
Event Offset
Triggers
Contrib. To
System
Status
Assert/D
e-assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
Power Unit Status
(Pwr Unit Status)
01h All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
04 - A/C lost
OK
As and
De
– Trig Offset
A X
05 - Soft power
control failure
06 - Power unit
failure
Fatal
Power Unit Redundancy1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully
Redundant
OK
As and
De
– Trig Offset
A X
01 - Redundancy
lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-
redundant:
sufficient
resources.
Transition from
full redundant
state.
Degraded
04 – Non-
redundant:
sufficient
resources.
Transition from
insufficient state.
Degraded
Vedere la pagina 165
1 2 ... 161 162 163 164 165 166 167 168 169 170 171 ... 191 192

Commenti su questo manuale

Nessun commento